| Product |
ZF 30 |
ZF 40 |
ZF 50 |
ZF 60 |
C3 300 |
| Rated air flow (m/s) |
2.6 |
2.6 |
2.6 |
2.6 |
0.25 |
| Initial pressure loss (Pa) |
20 |
34 |
38 |
60 |
15 |
| Final pressure loss (Pa) |
250 |
250 |
450 |
450 |
450 |
| Average efficiency (%) |
35 |
42 |
52 |
61 |
51 |
| Average arrestance (%) |
81 |
93 |
98 |
99 |
97 |
| Dust Holding Capacity (g/m2) |
500 |
458 |
288 |
220 |
330 |
| Washability |
Disposable |
Disposable |
Disposable |
Disposable |
Disposable |
| Classification (acc. EN779:2002) |
G3 |
G4 |
F5 |
F6 |
F5 |
| Typical use |
|
|
|
|
|
| Filter styles |
|
|
|
|
|
| Product |
FF 560 G |
CC 600 G |
| Rated air flow (m/s) |
0.25 |
0.25 |
| Initial pressure loss (Pa) |
25 |
25 |
| Final pressure loss (Pa) |
450 |
450 |
| Average efficiency (%) |
46 |
55 |
| Average arrestance (%) |
96 |
98 |
| Dust Holding Capacity (g/m2) |
419 |
430 |
| Washability |
Disposable |
Disposable |
| Classification (acc. EN779:2002) |
F5 |
F5 |
| Typical use |
|
|
| Filter styles |
|
|
| All ZF media figures have been tested in extended surface form. All other media listed are for tests conducted in flat pad configuration. |
| All of the above listed air filter media (excluding IFM 103) conform to all European Union and U.S. fire classification standards (e.g. DIN 53438-F1 and UL 900-class 2) and are self-extinguishing. |
 |
For intake air filtration and/or re-circulated air filtration e.g. for the ventilation of schools, department stores, hospitals etc. also for pre-filtration before fine air filtration |
 |
For intake air filtration and/or re-circulated air filtration e.g. for the ventilation of factories, warehouses etc. also for pre-filtration before fine or very fine air filtration |
 |
For intake fine air filtration and/or re-circulated air filtration e.g. for the ventilation of computer rooms etc. also for pre-filtration before very fine air filtration or carbon and gas phase filtration |
 |
For intake air fine filtration and/or re-circulated air filtration e.g. for the ventilation of laboratories etc. also for pre-filtration before very fine air filtration , carbon, gas phase or HEPA filtration |
 |
For intake air filtration and/or re-circulated air filtration for paint spray booths and paint spray plants of all types. |
 |
Available in rolls and cut mats |
 |
Available in panel and extended surface panel style air filters |
 |
Available in extended surface bag and pocket style air filters |
| If you have any questions or queries relating to the content of this page or any technical questions relating to air filters, spray booths, Peregrine Industries, Filtrair, Filtration Group or GFS or any product on this site, please contact us through our contacts page |
Due to ongoing product development, we reserve the right to alter any product specifications or prices as is necessary. |
|